SPECIAL FEATURES :
Extended >1000 ~ 1500V DC range suitable for solar
AutoCheck Voltage & Ohms
VFD-V & VFD-Hz function
5ms CREST-MAX capture mode (Peak Hold)
Autoranging Relative -Zero mode
Display Hold function
EF-Detection (NCV)
Backlight LCD Display
Auto Power Off
Diode Test & Continuity Test
PC Interface (Optional)
GENERAL SPECIFICATIONS :
Sensing : TRMS sensing
Jaw Opening : 55mm max.
Display : 3-5/6 digits 6000 counts & 3½ digits 1,999 counts for Hz.
Update Rate : 5 per second nominal
Polarity : Automatic
Low Battery : Below approx 2.4V
Operating Temperature : 0 °C to 40 °C
Relative Humidity : Maximum 80% R. H. for temperature upto 31°C decreasing linearly to 50% Relative Humidity at 40°C
Storage Temperature : -20°C to 60°C, < 80% R.H. (With battery removed)
Altitude : Operating below 2000m
Temperature Coefficient : nominal 0.15 x (specified accuracy) / °C @ (0°C--18°C or 28°C--40°C), or otherwise specified
Power supply : Standard 1.5V AAA Battery x 2.
Power Consumption : Typical 14mA for Current function, & 5.2mA for others.
APO Timing : Idle for 34 minutes
APO Consumption : 10uA typical
Dimension : 264(L) x 97(W) x 43(H) mm
Weight : Approx. 608gm.
Accessories : Test leads (pair), user’s manual, Bkp60 banana plug
K-type Thermocouple x 1 & carrying case.
SAFETY :
Double insulation per IEC/EN61010-1 2 Ed., UL61010-1 2nd Ed., & CAN/CSA C22.2 No.61010.1-0.92 to Category CAT IV 1000V AC & DC.
Transient Protection : 12 kV (1.2/50us surge)
Overload Protection :
Clamp-on jaws : 2000A rms continuous “ + ” & COM Terminals (all other functions) : 1000V rms.
Pollution degree : 2
EMC : Meets EN61326-1:2006 (EN55022,EN61000-3-2,EN61000-3-3,
EN61000-4-2, EN61000-4-3, EN61000-4-4,EN61000-4-5,EN61000-4-6,
EN61000-4-8,EN61000-4-11)
In an RF field of 3V/m :
Capacitance function is not specified
Other function ranges : Total Accuracy = Specified Accuracy + 200 digits
Performance above 3V/m is not specified.