Cart
Sign In

Sorry! Zebronics 1KVA Zeb-OU1K2 UPS Power Supply ( ) is sold out.

Compare Products
Clear All
Let's Compare!

Zebronics 1KVA Zeb-OU1K2 UPS Power Supply ( )

This product has been sold out

We will let you know when in stock
notify me

Featured

Highlights

  • Zebronics
  • Type:Power Supply
  • Number of Sockets:3
  • SUPC: SDL527299129

Description

ZEBRONICS Online UPS is specifically designed for operations in poor power areas. They provide high power density with long backup time in compact size. It’s ideal for ATMs, banking and other businesses with critical applications. Users could also adjust charging current from 1A to 6A according to different applications.






Features


Online Ups-1KVA

Microprocessor Based Control

LCD Display - Load Level, Battery Level, Ac Mode, Battery Mode,

Bypass Mode & Fault Indicators

Generator Compatible

Wide Input Voltage Range

Inbuilt Battery

Eco Mode For Energy Saving

User Selectable Output Voltage

Zero Transfer Time

Power Management Software








Specifications


CAPACITY 1000 VA / 800 W

INPUT

Voltage Range

Low Line Transfer 160VAC/140VAC/120VAC/110VAC±5% (Ambient Temp.<35°C)
(based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0)

Low Line Restore 175VAC/155VAC/135VAC/125VAC ± 5 % (Ambient Temp.<35°C)
( based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0)

High Line Transfer 280 VAC ± 5 %

High Line Restore 270 VAC ± 5 %

Frequency Range 40Hz ~ 70 Hz

Phase Single phase with ground

Power Factor ≥ 0.99 @ nominal voltage (input voltage)

OUTPUT

Output voltage 200/208/220/230/240VAC

AC Voltage Regulation ±1% (Batt. Mode)

Frequency Range 47 ~ 53 Hz or 57 ~ 63 Hz (Synchronized Range)

Frequency Range (Batt. Mode) 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz

Overload Ambient Temp.<35°C
105%~110%: UPS shuts down after 10 minutes at battery mode or transfer to bypass when the utility is normal.
110%~130%: UPS shuts down after 1minute at battery mode or transfer to bypass when the utility is normal.
>130%:UPS shuts down after 3seconds at battery mode or transfer to bypass when the utility is normal.

Current Crest Ratio 3:1

Harmonic Distortion ≤3 % THD (linear load); = 6 % THD (non-linear load)

Transfer Time AC Mode to Batt. Mode : Zero
Inverter to Bypass : 4 ms (Typical)

Waveform (Batt. Mode) Pure Sinewave

EFFICIENCY

AC Mode 88%

Battery Mode 83%

BATTERY

Battery Type 12 V / 9 AH

Numbers 2

Recharge Time 4 hours recover to 90% capacity (Typical)

Charging Current 1.0 A (max.)

Charging Voltage 27.4 VDC ±1%

PHYSICAL

Dimension 282 x 145 x 220mm (D x W x H )

Net. Weight 9.8 kg

ENVIRONMENT

Operation Humidity 20-90 % RH @ 0- 40°C (non-condensing)

Noise Level Less than 50dBA @ 1 Meter

MANAGEMENT

Smart RS-232 or USB Supports Windows® XP/Vista/7/8/10, Linux, Unix and MAC







2 years warranty. All India on sight support at customer location

Terms & Conditions

The images represent actual product though color of the image and product may slightly differ.